Model Room Check

Notes: I dont want analyser available because ... ok!
  • Values which are outside expected bounds are highlighted, we would recommend that these rooms are inspected carefully.
  • To allow for sloping ceilings, the Floor / Ceiling ratio is calculated from the area of the floor and the area of the projection to the horizontal of the ceiling.
  • All internal areas are calculated from the inner volume of a room (using wall thicknesses) where that exists.
  • A Missing Surfaces Area value greater than zero may indicate that the surfaces of a room do not join cleanly, or overlap, or are missing. Using the model viewer will help identify these gaps.
Room
Volume
(m³)
Area (m²)
Ratio
Volume
to Area
(m)
Area ratios
Missing
Surfaces
Area
(m²)
Name
ID
Floor
Ceiling
External Walls
Internal Walls
Total Glazing
Ceiling holes / Ceiling
Floor holes / Floor
Floor / Ceiling
Total Wall / Floor
External Wall / Floor
Window / Wall
1 KARAOKE RM
00114408
58.1
18.4
18.4
67.7
54.2
0.0
3.150
0.000
0.000
1.000
2.939
3.673
0.000
0.000
2 KARAOKE RM
00120850
59.7
18.9
18.9
65.9
57.5
0.0
3.150
0.000
0.000
1.000
3.033
3.479
0.000
0.000
3 KARAOKE RM
00120852
68.9
21.9
21.9
83.1
72.2
3.7
3.150
0.000
0.000
1.000
3.300
3.797
0.051
0.000
4 KARAOKE RM
00123632
60.3
19.1
19.1
66.3
57.8
0.0
3.150
0.000
0.000
1.000
3.022
3.466
0.000
0.000
5 PNGU
00125456
44.2
14.0
14.0
67.7
54.2
0.0
3.150
0.000
0.000
1.000
3.861
4.825
0.000
0.000
6 WC
00125460
11.7
3.7
3.7
33.4
25.8
0.0
3.150
0.000
0.000
1.000
6.979
9.018
0.000
0.000
7 WC
00125536
12.3
3.9
3.9
30.8
25.8
0.0
3.150
0.000
0.000
1.000
6.624
7.890
0.000
0.000
8 VUON TRONG
00136377
27.9
7.1
7.1
43.8
42.3
0.0
3.947
0.938
0.000
1.000
5.979
6.193
0.000
0.000
9 LE TAN
00136379
34.2
10.8
10.8
50.2
46.6
0.0
3.174
0.028
0.000
1.000
4.330
4.665
0.000
0.000
10 KHACH DOI
00136381
30.5
9.7
9.7
44.8
39.6
0.0
3.150
0.000
0.000
1.000
4.087
4.624
0.000
0.000
11 HANH LANG
00136383
69.5
22.1
22.1
97.0
85.9
0.0
3.150
0.000
0.000
1.000
3.892
4.398
0.000
0.000
12 SANH DOI
00136390
40.3
12.8
12.8
73.9
64.6
0.0
3.150
0.000
0.000
1.000
5.056
5.780
0.000
0.000
13 WC
00136394
11.7
3.7
3.7
33.4
25.8
0.0
3.150
0.000
0.000
1.000
6.979
9.018
0.000
0.000
14 SANH TANG
00136396
23.4
7.4
7.4
49.8
38.1
7.0
3.150
0.000
0.000
1.000
5.134
6.712
0.180
1.360
15 THANG
00136398
26.5
6.6
6.6
44.4
41.2
7.8
4.000
1.000
1.000
1.000
6.214
6.703
0.184
1.360
16 KARAOKE RM
00136404
157.5
50.0
50.0
108.9
95.8
0.0
3.150
0.000
0.000
1.000
1.916
2.178
0.000
0.000
17 KARAOKE RM
00136407
58.1
18.4
18.4
63.0
54.2
0.0
3.150
0.000
0.000
1.000
2.939
3.419
0.000
0.000
18 WC
00136409
11.7
3.7
3.7
30.8
25.8
0.0
3.150
0.000
0.000
1.000
6.979
8.313
0.000
0.000
19 SANH TANG
00136411
23.4
7.4
7.4
44.0
38.1
0.0
3.150
0.000
0.000
1.000
5.134
5.926
0.000
0.000
21 DE XE
00136431
126.5
40.2
40.2
93.0
81.5
12.7
3.150
0.000
0.000
1.000
2.029
2.315
0.156
0.000
22 PHONG THO
00137074
50.0
15.9
15.9
60.3
52.1
12.9
3.150
0.000
0.000
1.000
3.284
3.803
0.247
0.000
23 LOGIA
00158014
29.4
9.3
9.3
51.8
44.8
18.1
3.150
0.000
0.000
1.000
4.812
5.564
0.403
0.000


NhiHoang 12/Aug/2011
Contents:



Energy and Carbon Results
Proposed building energy use
105.71
MWh/yr
Proposed building carbon emissions
45.8
tonnes CO2
Energy breakdown:
Heating
26%
Cooling
29%
Lights
6%
Equipment
39%
The Energy & Carbon results are generated by the ApacheSim module. ApacheSim is a rigorous building thermal simulation approach that conforms to ANSI / ASHRAE Standard 140.
To find out more go to:
Architecture 2030 Challenge - summary
Current design meets 2030 Challenge Target for:
Does not meet current target
Design Building Energy Use Intensity:
325 kWh/m2
(Design EUI = Energy / Building Area)
Average Building Energy Use Intensity:
184 kWh/m2
(Used to generate 2030 Challenge Targets)
Building Type:
Multi-Family, 2 to 4 units (National Average)
Analysis Details: 

Location: 
Tan Son Hoa, Viet Nam
(10.76N, 106.65E)
Climate File:
BangkokIWEC.fwt
Calculated:
12/Aug/2011 at 11:46
Calculation period:
01/Jan - 31/Dec
The Architecture 2030 Challenge provides a roadmap of targets for US building projects culminating in being carbon neutral by 2030
Implementation of the Challenge requires the use of targets by building type derived from current building stock benchmarks
Challenge targets for selected building type:
Year
%
reduction
kWh/
m2
2005
50
92
Current
60
73
2015
70
55
2020
80
37
2025
90
18
2030
100
0
For certain building types targets are calculated using Energy Star methodology where energy consumption is not direct % reduction against average
Climate Energy Metric
Climate Energy Metric 
24 hour use 65.9 kWh/yr
Proposed hours of use 65.9 kWh/yr

Using the local fuel mix 29.5 kgCO2/yr
The Climate Energy Index is simple global unitary measure of energy required to maintain air at ASHRAE 55: 1981 comfort conditions. The Index is solely dependant on the climate data.
Building simulation results can be compared with the Index to provide a simple measure of performance in the context of global climate